  "schema_version": "2.0",
  "run_id": "assembly-seed348",
  "backend": "Isaac Lab PhysX on bimanual YAM",
  "simulation_task_passed": false,
  "production_ready": false,
  "production_blockers": [
    "Physical hardware validation is not performed",
    "Contact readings are sampled at the control rate. Substep peak coverage is not certified",
    "Independent wrist sensor calibration and safety validation are outstanding"
  ],
  "checks": {
    "telemetry_finite": true,
    "telemetry_contiguous": true,
    "contact_force_available": true,
    "contact_torque_available": true,
    "no_sensor_errors": true,
    "complete_assembly_sequence": false,
    "seating": false,
    "pin_engagement": false,
    "sampled_force_limits": true,
    "sampled_torque_limit": true,
    "sustained_pull": false,
    "observed_motion": false,
    "arms_released": false
  },
  "blockers": [
    "complete_assembly_sequence",
    "seating",
    "pin_engagement",
    "sustained_pull",
    "observed_motion",
    "arms_released"
  ],
  "metrics": {
    "samples": 821,
    "duration_s": 40.99999999999981,
    "final_gap_mm": 44.63285446166992,
    "final_yaw_error_deg": 0.056492723524570465,
    "final_lateral_error_mm": 51.91930389404297,
    "final_relative_position_mm": [
      24.438442662358284,
      45.80803960561752,
      43.632857501506805
    ],
    "final_pin_position_mm": [
      -139.46707546710968,
      -94.20032054185867,
      -15.599953010678291
    ],
    "peak_sampled_axial_n": 9.413236613585786,
    "peak_sampled_lateral_n": 3.129394524648043,
    "peak_sampled_torque_nm": 0.1215912871244045,
    "longest_pull_duration_s": 0.0,
    "observed_motion_deg": 0
  },
  "telemetry_sha256": "9c480bd8d11130d1869e6e6111ec153e5f7bd50f318ba5784066812adfc7b5b7",
  "events": [
    {
      "time_s": 10.000000000000007,
      "phase": "align",
      "reason": "Transport completed. Using measured relative pose."
    },
    {
      "time_s": 12.000000000000036,
      "phase": "insert",
      "reason": "Measured alignment is within 1 mm and 1 degree"
    },
    {
      "time_s": 17.000000000000107,
      "phase": "retract",
      "reason": "Loaded insertion is showing less than 0.5 mm progress in one second"
    },
    {
      "time_s": 21.000000000000163,
      "phase": "align",
      "reason": "Bounded recovery budget check"
    },
    {
      "time_s": 41.049999999999805,
      "phase": "safe_stop",
      "reason": "Alignment timeout"
    }
  ]
}