  "schema_version": "2.0",
  "run_id": "cli-regression205-v17",
  "backend": "Isaac Lab PhysX on bimanual YAM",
  "simulation_task_passed": false,
  "production_ready": false,
  "production_blockers": [
    "Physical hardware validation is not performed",
    "Contact readings are sampled at the control rate. Substep peak coverage is not certified",
    "Independent wrist sensor calibration and safety validation are outstanding"
  ],
  "checks": {
    "telemetry_finite": true,
    "telemetry_contiguous": true,
    "contact_force_available": true,
    "contact_torque_available": true,
    "no_sensor_errors": true,
    "complete_assembly_sequence": false,
    "seating": false,
    "pin_engagement": false,
    "sampled_force_limits": true,
    "sampled_torque_limit": true,
    "sustained_pull": false,
    "observed_motion": false,
    "arms_released": false
  },
  "blockers": [
    "complete_assembly_sequence",
    "seating",
    "pin_engagement",
    "sustained_pull",
    "observed_motion",
    "arms_released"
  ],
  "metrics": {
    "samples": 706,
    "duration_s": 35.250000000000135,
    "final_gap_mm": 43.09864044189453,
    "final_yaw_error_deg": 0.014555281959474087,
    "final_lateral_error_mm": 1.129710078239441,
    "final_relative_position_mm": [
      0.8074195357039571,
      0.7901384378783405,
      42.09864139556885
    ],
    "final_pin_position_mm": [
      -139.54567909240723,
      -94.31606531143188,
      -15.599853359162807
    ],
    "peak_sampled_axial_n": 3.7918618622764426,
    "peak_sampled_lateral_n": 3.030624629102032,
    "peak_sampled_torque_nm": 0.11780354637476062,
    "longest_pull_duration_s": 0.0,
    "observed_motion_deg": 0
  },
  "telemetry_sha256": "c00cb09165bff1d6c21543cbaea830a27c4ea1bf826678a9e06507d1ada73323",
  "events": [
    {
      "time_s": 10.000000000000007,
      "phase": "align",
      "reason": "Transport completed. Using measured relative pose."
    },
    {
      "time_s": 12.250000000000039,
      "phase": "insert",
      "reason": "Measured alignment is within 1 mm and 1 degree"
    },
    {
      "time_s": 26.250000000000238,
      "phase": "retract",
      "reason": "Insertion timeout with unresolved gap"
    },
    {
      "time_s": 30.250000000000295,
      "phase": "align",
      "reason": "Bounded recovery budget check"
    },
    {
      "time_s": 34.60000000000017,
      "phase": "insert",
      "reason": "Measured alignment is within 1 mm and 1 degree"
    }
  ]
}